ADG5412BF/ADG5413BF. Data Sheet. −40°C to. Parameter +25°C. +85°C. +125°C Unit Test. Conditions/Comments

ADG5412BF/ADG5413BF Data Sheet −40°C to Parameter +25°C +85°C +125°C Unit Test Conditions/Comments

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 22 link to page 22 link to page 21 link to page 20 link to page 20 link to page 20 link to page 21 link to page 21 link to page 22 link to page 19 link to page 19 link to page 19 link to page 19 link to page 19
ADG5412BF/ADG5413BF Data Sheet −40°C to −40°C to Parameter +25°C +85°C +125°C Unit Test Conditions/Comments
Output Voltage V min High, VOH 2.0 V min Low, VOL 0.8 V max DYNAMIC CHARACTERISTICS1 tON 400 ns typ RL = 300 Ω, CL = 35 pF 495 525 550 ns max VS = 10 V, see Figure 47 tOFF 410 ns typ RL = 300 Ω, CL = 35 pF 510 545 555 ns max VS = 10 V, see Figure 47 Break-Before-Make Time Delay, tD 285 ns typ RL = 300 Ω, CL = 35 pF (ADG5413BF Only) 185 ns min VS1 = VS2 = 10 V, see Figure 46 Overvoltage Response Time, tRESPONSE 460 ns typ RL = 1 kΩ, CL = 2 pF, see Figure 41 585 615 630 ns max Overvoltage Recovery Time, tRECOVERY 720 ns typ RL = 1 kΩ, CL = 2 pF, see Figure 42 930 1050 1100 ns max Interrupt Flag Response Time, tDIGRESP 85 115 ns typ CL = 10 pF, see Figure 43 Interrupt Flag Recovery Time, tDIGREC 60 85 μs typ CL = 10 pF, see Figure 44 600 ns typ CL = 10 pF, RPULLUP = 1 kΩ, see Figure 45 Charge Injection, QINJ −680 pC typ VS = 0 V, RS = 0 Ω, CL = 1 nF, see Figure 48 Off Isolation −70 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz, see Figure 35 Channel-to-Channel Crosstalk −90 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz, see Figure 36 Total Harmonic Distortion Plus Noise, THD + N 0.0015 % typ RL = 10 kΩ, VS = 15 V p-p, f = 20 Hz to 20 kHz, see Figure 40 −3 dB Bandwidth 270 MHz typ RL = 50 Ω, CL = 5 pF, see Figure 39 Insertion Loss −0.72 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz, see Figure 39 CS (Off ) 13 pF typ VS = 0 V, f = 1 MHz CD (Off ) 12 pF typ VS = 0 V, f = 1 MHz CD (On), CS (On) 24 pF typ VS = 0 V, f = 1 MHz POWER REQUIREMENTS VDD = 16.5 V, VSS = −16.5 V, digital inputs = 0 V, 5 V, or VDD Normal Mode IDD 0.9 mA typ 1.2 1.3 mA max IGND 0.4 mA typ 0.55 0.6 mA max ISS 0.5 mA typ 0.65 0.7 μA max Fault Mode VS = ±55 V IDD 1.2 mA typ 1.6 1.8 mA max IGND 0.8 mA typ 1.0 1.1 mA max ISS 0.5 mA typ 1.0 1.8 mA max VDD/VSS ±5 V min GND = 0 V ±22 V max GND = 0 V 1 Guaranteed by design; not subject to production test. Rev. B | Page 4 of 28 Document Outline FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAMS GENERAL DESCRIPTION PRODUCT HIGHLIGHTS TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ±15 V DUAL-SUPPLY ±20 V DUAL-SUPPLY 12 V SINGLE-SUPPLY 36 V SINGLE-SUPPLY CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS TERMINOLOGY THEORY OF OPERATION SWITCH ARCHITECTURE ESD Performance Trench Isolation FAULT PROTECTION Power-On Protection Power-Off Protection Digital Input Protection Overvoltage Interrupt Flag APPLICATIONS INFORMATION POWER SUPPLY RAILS POWER SUPPLY SEQUENCING PROTECTION SIGNAL RANGE LOW IMPEDANCE CHANNEL PROTECTION HIGH VOLTAGE SURGE SUPPRESSION INTELLIGENT FAULT DETECTION LARGE VOLTAGE, HIGH FREQUENCY SIGNALS OUTLINE DIMENSIONS ORDERING GUIDE