Datasheet Texas Instruments OPA170ASDRLTEP — Datenblatt

HerstellerTexas Instruments
SerieOPA170-EP
ArtikelnummerOPA170ASDRLTEP
Datasheet Texas Instruments OPA170ASDRLTEP

Verbessertes Produkt 36-V-Einzelversorgung, Operationsverstärker mit geringer Leistung 5-SOT-5X3 -40 bis 150

Datenblätter

36-V Single Supply, Low Power Op-Amp datasheet
PDF, 1.4 Mb, Revision: A, Datei veröffentlicht: Dec 27, 2012
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Verpackung

Pin5
Package TypeDRL
Industry STD TermSOT-5X3
JEDEC CodeR-PDSO-N
Package QTY250
CarrierSMALL T&R
Device MarkingDAQ
Width (mm)1.2
Length (mm)1.6
Thickness (mm).55
Pitch (mm).5
Max Height (mm).6
Mechanical DataHerunterladen

Parameter

Additional FeaturesEMI Hardened
ArchitectureCMOS
CMRR(Min)87 dB
CMRR(Typ)120 dB
GBW(Typ)1.2 MHz
IIB(Max)15 pA
Iq per channel(Max)0.145 mA
Iq per channel(Typ)0.11 mA
Number of Channels1
Offset Drift(Typ)0.3 uV/C
Operating Temperature Range-40 to 150 C
Output Current(Typ)17 mA
Package GroupSOT-5X3
Package Size: mm2:W x L5SOT-5X3: 3 mm2: 1.6 x 1.6(SOT-5X3) PKG
Rail-to-RailIn to V-,Out
RatingHiRel Enhanced Product
Slew Rate(Typ)0.4 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)2.7 +5V=5, +/-5V=10
Vn at 1kHz(Typ)19 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)1.8 mV

Öko-Plan

RoHSCompliant

Anwendungshinweise

  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revision: A, Datei veröffentlicht: Mar 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Serie: OPA170-EP (2)

Herstellerklassifikation

  • Semiconductors > Space & High Reliability > Amplifier > Operational Amplifiers