GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE. Ambient Environment.  . ■

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE Ambient Environment   ■

Modelllinie für dieses Datenblatt

Textversion des Dokuments

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE Ambient Environment   ■ Usage, Transport, and Storage Conditions During usage, storage, or transportation, avoid locations  ● Icing subjected to direct sunlight and maintain normal  Condensation or other moisture may freeze on relays  temperature, humidity and pressure conditions. when the temperature become lower than 0 ℃.This    ●Temperature/Humidity/Pressure icing causes the sticking of movable portion, the  When transporting or storing relays while they are tube  operation delay and the contact conduction failure etc.  packaged, there are cases the temperature may differ  Panasonic Industry Co., Ltd. does not guarantee the  from the allowable range. In this case be sure to check  failures caused by the icing. the individual specifications. The heat conduction by the equipment may accelerate  Also allowable humidity level is influenced by  the cooling of relay itself and the icing may occur.  temperature, please check charts shown below and  Please conduct product evaluations in the worst  use relays within mentioned conditions. ( Allowable  condition of the actual usage.  temperature values differ for each relays, please refer  to the relay's individual specifications. ) ● Low temperature and low humidity 1)  Temperature:  The plastic becomes brittle if the relay is exposed to a  The tolerance temperature range differs for  low temperature, low humidity environment for long  each relays, please refer to the relay's individual  periods of time.  specifications    2)  Humidity: 5 to 85 % RH ● High temperature and high humidity Storage for extended periods of time ( including  Humidity (% RH) transportation periods ) at high temperature or high  humidity levels or in atmospheres with organic gases  or sulfide gases may cause a sulfide film or oxide film  85 to form on the surfaces of the contacts and/or it may  interfere with the functions. Check out the atmosphere  Allowable range in which the units are to be stored and transported.  Avoid icing Avoid con- when used at densation when  temperatures used at tem- ● Package lower than 0°C peratures higher  than 0°C In terms of the packing format used, make every effort  5 to keep the effects of moisture, organic gases and  -40 0 85 sulfide gases to the absolute minimum.  Ambient temperature (℃) 3)  Pressure: 86 to 106 kPa  ● Silicon When a source of silicone substances ( silicone rubber,    ●Dew condensation silicone oil, silicone coating materials and silicone filling  Condensation occurs when the ambient temperature  materials etc. ) is used around the relay, the silicone gas  drops suddenly from a high temperature and humidity,  ( low molecular siloxane etc. ) may be produced.  or the relay is suddenly transferred from a low ambient  This silicone gas may penetrate into the inside of the  temperature to a high temperature and humidity.  relay. When the relay is kept and used in this condition,  Condensation causes the failures like insulation  silicone compound may adhere to the relay contacts  deterioration, wire disconnection and rust etc. which may cause the contact failure. Do not use any  Panasonic Industry Co., Ltd. does not guarantee the  sources of silicone gas around the relay ( Including  failures caused by condensation. plastic sealed types ).  The heat conduction by the equipment may accelerate  the cooling of device itself, and the condensation may  ● NOx Generation occur. When relay is used in an atmosphere high in humidity  Please conduct product evaluations in the worst  to switch a load which easily produces an arc, the NOx  condition of the actual usage. ( Special attention should  created by the arc and the water absorbed from outside  be paid when high temperature heating parts are close  the relay combine to produce nitric acid.  to the device. Also please consider the condensation  This corrodes the internal metal parts and adversely  may occur inside of the device. ) affects operation.  Avoid use at an ambient humidity of 85 % RH or higher   ( at 20 ℃ ). If use at high humidity is unavoidable,  please contact our sales representative. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industry.panasonic.com Panasonic Industry Co., Ltd. 2024 ASCTB412E 202408 ー 7 ー