Datasheet E2B (Omron) - 8

HerstellerOmron
BeschreibungCylindrical Proximity Sensor
Seiten / Seite22 / 8 — E2B. Size. M18. Sensing. Single. Double. distance. Type. Shielded. …
Dateiformat / GrößePDF / 6.9 Mb
DokumentenspracheEnglisch

E2B. Size. M18. Sensing. Single. Double. distance. Type. Shielded. Unshielded. Item. Model. E2B-M18. S05. N10. S08. N16. Sensing distance. Setting distance

E2B Size M18 Sensing Single Double distance Type Shielded Unshielded Item Model E2B-M18 S05 N10 S08 N16 Sensing distance Setting distance

Modelllinie für dieses Datenblatt

E2B

Textversion des Dokuments

E2B Size M18 Sensing Single Double distance Type Shielded Unshielded Shielded Unshielded Item Model E2B-M18
@
S05 E2B-M18
@
N10 E2B-M18
@
S08 E2B-M18
@
N16 Sensing distance
5 mm ± 10% 10 mm ± 10% 8 mm ± 10% 16 mm ± 10%
Setting distance
0 to 4 mm 0 to 8 mm 0 to 6.4 mm 0 to 12.8 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object
18 × 18 × 1 mm 30 × 30 × 1 mm 24 × 24 × 1 mm 48 × 48 × 1 mm
(mild steel ST37) Response frequency (See note 1.)
600 Hz 400 Hz 500 Hz 400 Hz
Power supply voltage
10 to 30 VDC. (including 10% ripple (p-p))
Current consumption
10 mA max. -B models: PNP open collector
Output type
-C models: NPN open collector
Load current
200 mA max. (30 VDC max.)
Control output Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
-B1/-C1 models: NO
(with sensing object approaching)
-B2/-C2 models: NC Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Protection circuit
Short-circuit protection
Ambient air temperature
Operation and storage : -25 to 70ºC (with no icing or condensation) ±10% max. of sensing distance at 23ºC within temperature range of -10 to 55ºC
Temperature influence
±15% max. of sensing distance at 23ºC within temperature range of -25 to 70ºC
Ambient humidity
Operation and Storage: 35 to 95%
Voltage influence
±1% max. of sensing distance in 24 VDC ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2) Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connecting method
Connector models (M12-4pin)
Weight Pre-wired model
Short body: Approx. 95 g, Long body: Approx. 110 g (See note 2.)
(packaged) Connector model
Short body: Approx. 60 g, Long body: Approx. 80 g
Case
Brass-nickel plated
Sensing surface
PBT
Material Cable
Standard cable is 4 mm dia. PVC.
Clamping nut
Brass-nickel plated
Toothed washer
Zinc-plated iron Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance. 2. In case of ‘WP’ cable type.
8