10 | 60 Bosch Sensortec | BME280 Data sheet 100 Relative humidity [%] 80 60 40 20 0 -40 -20 0 20 40 Temperature [°C] 60 80 Figure 1: humidity sensor operating range 1.3 Pressure sensor specification Table 3: Pressure parameter specification Parameter Symbol Condition Min Typ Max Unit Operating temperature range TA operational -40 25 +85 °C full accuracy 0 +65 Operating pressure range P full accuracy 300 1100 hPa IDD,LP 1 Hz forced mode, pressure and temperature, lowest power 4.2 µA Supply current Modifications reserved | Data subject to change without notice 2.8 Document number: BST-BME280-DS001-23 Revision_1.23_012022