Datasheet ADG4612, ADG4613 (Analog Devices) - 8

HerstellerAnalog Devices
BeschreibungPower-Off Protection ±5 V, +12 V, Quad SPST Switches with 5 Ω On Resistance
Seiten / Seite24 / 8 — ADG4612/ADG4613. Parameter. 25°C. −40°C to +85°C. Unit. Test …
Dateiformat / GrößePDF / 397 Kb
DokumentenspracheEnglisch

ADG4612/ADG4613. Parameter. 25°C. −40°C to +85°C. Unit. Test Conditions/Comments. CONTINUOUS CURRENT PER CHANNEL, SX OR DX

ADG4612/ADG4613 Parameter 25°C −40°C to +85°C Unit Test Conditions/Comments CONTINUOUS CURRENT PER CHANNEL, SX OR DX

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 15 link to page 15 link to page 15 link to page 15
ADG4612/ADG4613 Parameter 25°C −40°C to +85°C Unit Test Conditions/Comments
Channel-to-Channel Crosstalk −71 dB typ RL = 50 Ω, CL = 5 pF, f = 100 kHz; see Figure 29 Total Harmonic Distortion + Noise, THD + N 0.85 % typ RL = 110 Ω, f = 20 Hz to 20 kHz, VS = 3.5 V p-p; see Figure 31 Insertion Loss −0.5 dB typ RL = 50 Ω, CL = 5 pF; f = 1 MHz; see Figure 30 −3 dB Bandwidth 293 MHz RL = 50 Ω, CL = 5 pF; see Figure 30 typ CS (Off ) 14 pF typ VS = 0 V, f = 1 MHz CD (Off ) 14 pF typ VS = 0 V, f = 1 MHz CD (On), CS (On) 50 pF typ VS = 0 V, f = 1 MHz POWER REQUIREMENTS Normal Mode VDD = 5.5 V, VSS = 0 V IDD 90 μA typ Digital inputs = 0 V or VDD 140 165 μA max Isolation Mode VDD = 5.5 V, VSS = 0 V or floating IDD 90 μA typ Digital inputs = 0 V or 5.5 V 140 165 μA max VS = 1 V/16 V, VD = 16 V/1 V 1 Guaranteed by design, not subject to production test.
CONTINUOUS CURRENT PER CHANNEL, SX OR DX Table 4. Parameter 25°C 85°C Unit
CONTINUOUS CURRENT, Sx OR Dx

VDD = +5 V, VSS = −5 V TSSOP (θJA = 112°C/W) 109 52 mA maximum LFCSP (θJA = 48.7°C/W) 160 83 mA maximum VDD = 12 V, VSS = 0 V TSSOP (θJA = 112°C/W) 113 56 mA maximum LFCSP (θJA = 48.7°C/W) 175 87 mA maximum VDD = 5 V, VSS = 0 V TSSOP (θJA = 112°C/W) 78 39 mA maximum LFCSP (θJA = 48.7°C/W) 118 56 mA maximum
POWER SUPPLY OPERATION
Temperature range is −40°C to +105°C, unless otherwise noted.
Table 5. Parameter Min Max Unit Comments
POWER SUPPLY VDD to VSS 16 V GND = 0 V VDD 2.7 16 V GND = 0 V VSS −5.5 0 V GND = 0 V DUAL SUPPLY VSS/VDD −5.5 +10.5 V VDD to VSS = 16 V, GND = 0 V SINGLE SUPPLY VDD 0 16 V VDD to VSS = 16 V, GND = 0 V, VSS = 0 V Analog Signal Range, VD, VS Normal Mode −5.5 VDD V VDD to VSS = 16 V maximum Isolation Mode −5.5 +16 V Most negative (VS ,VD, or VSS) to most positive (VS ,VD, Inx, or VDD) = 16 V maximum Rev. 0 | Page 8 of 24 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM PRODUCT HIGHLIGHTS TABLE OF CONTENTS SPECIFICATIONS 5 V DUAL SUPPLY 12 V SINGLE SUPPLY 5 V SINGLE SUPPLY CONTINUOUS CURRENT PER CHANNEL, SX OR DX POWER SUPPLY OPERATION ABSOLUTE MAXIMUM RATINGS THERMAL RESISTANCE ESD CAUTION PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS TERMINOLOGY THEORY OF OPERATION Normal Mode Isolation Mode Positive Fault Condition Negative Fault Condition; Negative Signal Handling APPLICATIONS INFORMATION Power Supply Sequencing OUTLINE DIMENSIONS ORDERING GUIDE