Datasheet Texas Instruments ADS122C04IRTET — Datenblatt

HerstellerTexas Instruments
SerieADS122C04
ArtikelnummerADS122C04IRTET

24-Bit-, 2kSPS-, 4-Kanal-, Low-Power-Delta-Sigma-ADC mit PGA-, Vref-, 2x IDACs und I2C-Schnittstelle 16-WQFN -40 bis 125

Datenblätter

ADS122C04 24-Bit, 4-Channel, 2-kSPS, Delta-Sigma ADC With I2C Interface datasheet
PDF, 2.1 Mb, Revision: A, Datei veröffentlicht: Mar 22, 2018

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin1616
Package TypeRTERTE
Industry STD TermWQFNWQFN
JEDEC CodeS-PQFP-NS-PQFP-N
Package QTY250250
CarrierSMALL T&RSMALL T&R
Device Marking122C122C4
Width (mm)33
Length (mm)33
Thickness (mm)0.750.75
Pitch (mm)0.50.5
Max Height (mm)0.80.8
Mechanical DataHerunterladenHerunterladen

Parameter

Analog Voltage AVDD(Max)5.5 V
Analog Voltage AVDD(Min)2.3 V
ArchitectureDelta-Sigma
Digital Supply(Max)5.5 V
Digital Supply(Min)2.3 V
Features50/60 Hz Rejection,Excitation Current Sources (iDACs),Oscillator,PGA,Temp Sensor,Small Size
Input Range(Max)2.85,5.6 V
Input Range(Min)-2.85,0 V
Input TypeDifferential,Single-Ended
InterfaceI2C
Multi-Channel ConfigurationMultiplexed
Number of input channels4
Operating Temperature Range-40 to 125 C
Package GroupTSSOP|16,WQFN|16
Package Size: mm2:W x L16TSSOP: 22 mm2: 4.4 x 5 (TSSOP|16),16WQFN: 9 mm2: 3 x 3 (WQFN|16) PKG
Power Consumption(Typ)1.4 mW
RatingCatalog
Reference ModeExt,Int
Resolution24 Bits
Sample Rate(Max)2 MSPS

Öko-Plan

RoHSCompliant

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: ADS122C04EVM
    ADS122C04 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Anwendungshinweise

  • Thermocouple Temperature Measurements Using Isolated Amplifiers (Rev. A)
    PDF, 145 Kb, Revision: A, Datei veröffentlicht: Aug 11, 2017
    The most common thermocouple in use today is the Type K. A Type-K thermocouple is inexpensive accurate and works reliably in harsh environments. Type-K thermocouples can measure temperatures ranging from –200°C to +1250°C and have a Seebeck coefficient of S = 41 μV/K at room temperature.
  • Low-Cost Single-Chip Diff Temp Measurement Solution Using Delta-Sigma ADCs (Rev. A)
    PDF, 486 Kb, Revision: A, Datei veröffentlicht: May 4, 2018
  • Reducing System Cost Size and Power in Isolated DAQ Systems Using ADS122U04 (Rev. A)
    PDF, 763 Kb, Revision: A, Datei veröffentlicht: Jun 15, 2017
  • RTD Ratiometric Measurements and Filtering Using the ADS1148 and ADS1248
    PDF, 563 Kb, Datei veröffentlicht: Mar 13, 2013
    The ADS1148 and ADS1248 family of devices are highly integrated delta-sigma (ΔΣ) converters that areoptimized for the measurement of temperature sensors including resistance temperature detectors(RTDs) thermocouples and thermistors. In a typical RTD measurement application the ADS1148 andADS1248 are configured in a ratiometric topology using the built-in IDAC current sources feeding thro
  • Example Temperature Measurement Applications Using the ADS1247 and ADS1248 (Rev. B)
    PDF, 189 Kb, Revision: B, Datei veröffentlicht: May 9, 2016
    This document discusses the use of the ADS1247 and ADS1248 precision analog-to-digital converters (ADCs) together with a resistive temperature device (RTD) and thermocouple to measure temperature. Included are detailed examples of the most common configurations of a two-wire RTD a three-wire RTD a four-wire RTD and a thermocouple with cold junction compensation. This document provides sufficien
  • A Basic Guide to Thermocouple Measurements
    PDF, 298 Kb, Datei veröffentlicht: Sep 28, 2018
    Thermocouples are common temperature sensors used in a wide variety of commercial and industrialapplications. While slightly less accurate than resistance temperature detectors (RTDs) thermocouplescover a wide temperature range are self-powered and have a fast response time. Their simpleconstruction make them inexpensive and durable. Because of the small sensor voltage and low noiserequ
  • A Basic Guide to RTD Measurements
    PDF, 333 Kb, Datei veröffentlicht: Jun 19, 2018
    RTDs or resistance temperature detectors are sensors used to measure temperature. These sensors arethe among the most accurate temperature sensors available covering large temperature ranges.However getting accurate measurements with precision analog-to-digital converters (ADCs) requiresattention to detail in design of measurement circuits and calculation of the measurement. This applica
  • Digital Filter Types in Delta-Sigma ADCs
    PDF, 219 Kb, Datei veröffentlicht: Jun 27, 2017
    This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide

Modellreihe

Herstellerklassifikation