Datasheet Texas Instruments SN65LBC184D — Datenblatt

HerstellerTexas Instruments
SerieSN65LBC184
ArtikelnummerSN65LBC184D
Datasheet Texas Instruments SN65LBC184D

RS-485-Transceiver mit integrierter Unterdrückung transienter Spannungen 8-SOIC -40 bis 85

Datenblätter

SNx5LBC184 Differential Transceiver With Transient Voltage Suppression datasheet
PDF, 1.1 Mb, Revision: I, Datei veröffentlicht: Jun 30, 2015
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Verpackung

Pin8
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY75
CarrierTUBE
Device Marking6LB184
Width (mm)3.91
Length (mm)4.9
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical DataHerunterladen

Parameter

Common Mode Range-7 to 12
DuplexHalf
Fail SafeOpen
Fault Protection-15 to 15 V
HBM ESD15 kV
ICC(Max)25 mA
IEC 61000-4-2 Contact30 +/- kV
IsolatedNo
No. of RX1
No. of TX1
Number of Nodes128
Operating Temperature Range-40 to 85 C
Package GroupSOIC
RatingCatalog
Signaling Rate(Max)0.25 Mbps
Supply Voltage(s)(Nom)5 V

Öko-Plan

RoHSCompliant

Anwendungshinweise

  • RS-485 at 230-kbps Over Uncontrolled Interconnect
    PDF, 408 Kb, Datei veröffentlicht: Apr 12, 2004
    This application report presents an evaluation of the SN65LBC184, SN65HVD22, and MAX487 transceivers in an uncontrolled impedance interconnection signaling at 230 kbps. The network used for the evaluation was identified as typical of that for building security.
  • RS-485 for Digital Motor Control Applications
    PDF, 180 Kb, Datei veröffentlicht: May 12, 2003
    This application report focuses on the benefits of using RS-485 signaling for motor control and motion control applications. This technology has several benefits for these applications in terms of noise immunity, wide common-mode voltage range, adequate data rate, and multipoint capability. Other applications also use RS-485 signaling to take advantage of these same benefits. Applications such as
  • RS-485 for E-Meter Applications (Rev. A)
    PDF, 311 Kb, Revision: A, Datei veröffentlicht: Aug 6, 2004
    This application report discusses the best practices for designing energy meter communication circuits using the RS-485 standard. Component selection and performance tradeoffs are covered with reference to relevant standards such as IEC 61036 and DL/T 645. Reference design details are provided to help energy meter engineers successfully complete their own circuit designs.
  • The RS-485 Unit Load and Maximum Number of Bus Connections
    PDF, 197 Kb, Datei veröffentlicht: Mar 15, 2004
    The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.

Modellreihe

Herstellerklassifikation

  • Semiconductors > Interface > RS-485/RS-422