Datasheet Intersil X9318 — Datenblatt

HerstellerIntersil
SerieX9318

Digital gesteuertes Potentiometer (XDCP)

Datenblätter

X9318 Datasheet
PDF, 477 Kb, Revision: 02-11-2017
Auszug aus dem Dokument

Preise

Verpackung

X9318WP8X9318WP8IX9318WP8IZX9318WS8X9318WS8IX9318WS8IT1X9318WS8IZX9318WS8IZT1X9318WS8T1X9318WS8ZX9318WS8ZT1
N1234567891011
Package8 Ld PDIP8 Ld PDIP8 Ld PDIP8 Ld SOIC8 Ld SOIC8 Ld SOIC T+R8 Ld SOIC8 Ld SOIC T+R8 Ld SOIC T+R8 Ld SOIC8 Ld SOIC T+R

Parameter

Parameters / ModelsX9318WP8X9318WP8IX9318WP8IZX9318WS8X9318WS8IX9318WS8IT1X9318WS8IZX9318WS8IZT1X9318WS8T1X9318WS8ZX9318WS8ZT1
# of Taps100100100100100100100100100100100
Number of Channels11111111111
DescriptionDigitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)Digitally Controlled Potentiometer (XDCP?)
Dual Supply Range (V)N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
End-to-End Tempco (В±ppm/В°C)300300300300300300300300300300300
FeaturesInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCCInternal charge pump to generate terminal voltage capability greater than VCC
ICC300 μA300 μA300 μA300 μA300 μA300 μA300 μA300 μA300 μA300 μA300 μA
Interface3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)
Max Operating Temp85 °C85 °C85 °C85 °C85 °C85 °C85 °C85 °C85 °C85 °C85 °C
Memory TypeNonvolatileNonvolatileNonvolatileNonvolatileNonvolatileNonvolatileNonvolatileNonvolatileNonvolatileNonvolatileNonvolatile
Middlepoint Ratiometric Tempco2020202020202020202020
Number of Channels11111111111
Operating Temperature Range-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85
Peak Temp240°C240°C240°C260°C260°C240°C260°C260°C
Qualification LevelStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandard
Resistance Options (kΩ)1010101010101010101010
Resistance Options (kО©)1010101010101010101010
Resistance TaperLinearLinearLinearLinearLinearLinearLinearLinearLinearLinearLinear
VCC (max)5.5 V5.5 V5.5 V5.5 V5.5 V5.5 V5.5 V5.5 V5.5 V5.5 V5.5 V
VCC (min)4.5 V4.5 V4.5 V4.5 V4.5 V4.5 V4.5 V4.5 V4.5 V4.5 V4.5 V
VL Max. Terminal Voltage8 V8 V8 V8 V8 V8 V8 V8 V8 V8 V8 V
VL Min. Terminal Voltage0 V0 V0 V0 V0 V0 V0 V0 V0 V0 V0 V
Wiper Current3 mA3 mA3 mA3 mA3 mA3 mA3 mA3 mA3 mA3 mA3 mA
Wiper Resistance40 О©40 О©40 О©40 О©40 О©40 О©40 О©40 О©40 О©40 О©40 О©
interface3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)3-Wire (Up/Down)

Öko-Plan

X9318WP8X9318WP8IX9318WP8IZX9318WS8X9318WS8IX9318WS8IT1X9318WS8IZX9318WS8IZT1X9318WS8T1X9318WS8ZX9318WS8ZT1
RoHSCompliantCompliantCompliantCompliantCompliant

Modellreihe

Herstellerklassifikation

  • Data Converters > Digital Potentiometers (DCPs) > DCPs