Datasheet Texas Instruments AMC1301DWVR — Datenblatt
| Hersteller | Texas Instruments | 
| Serie | AMC1301 | 
| Artikelnummer | AMC1301DWVR | 

Präzision, ± 250 mV Eingang, 3 µs Verzögerung, verstärkter isolierter Verstärker 8-SOIC -40 bis 125
Datenblätter
AMC1301 Precision, В±250-mV   Input, 3-µs Delay, Reinforced Isolated Amplifier datasheet
PDF, 1.5 Mb, Revision: D, Datei veröffentlicht: Jan 25, 2017
Auszug aus dem Dokument
Status
| Lifecycle Status | Active (Recommended for new designs) | 
| Manufacture's Sample Availability | Yes | 
Verpackung
| Pin | 8 | 
| Package Type | DWV | 
| Industry STD Term | SOIC | 
| JEDEC Code | R-PDSO-G | 
| Package QTY | 1000 | 
| Carrier | LARGE T&R | 
| Device Marking | AMC1301 | 
| Width (mm) | 7.5 | 
| Length (mm) | 5.85 | 
| Thickness (mm) | 2.65 | 
| Pitch (mm) | 1.27 | 
| Max Height (mm) | 2.8 | 
| Mechanical Data | Herunterladen | 
Parameter
| CMTI(Min) | 15 kV/µs | 
| Common Mode Rejection Ratio(Typ) | 92 dB | 
| Gain Non-Linearity (+/-)(Max) | 0.03 % | 
| Isolation Transient Overvoltage VIOTM (Peak) | 7000 V | 
| Isolation Working Voltage VIOWM (rms) | 1000 V | 
| Operating Temperature Range | -40 to 125 C | 
| Package Group | SOIC | 
| Package Size: mm2:W x L | 8SOIC: 67 mm2: 11.5 x 5.85(SOIC) PKG | 
| Rating | Catalog | 
| Small Signal Bandwidth(Typ) | 210 kHz | 
Öko-Plan
| RoHS | Compliant | 
Design Kits und Evaluierungsmodule
- Evaluation Modules & Boards: AMC1301EVM
AMC1301 Evaluation Module
Lifecycle Status: Active (Recommended for new designs) 
Anwendungshinweise
- How to Optimize Performance of AMC1304/05M25 in Voltage SensingPDF, 181 Kb, Datei veröffentlicht: Aug 31, 2015
 - How to Optimize Performance of AMC1304/05M05 in Voltage SensingPDF, 178 Kb, Datei veröffentlicht: Aug 31, 2015
 - Thermocouple Temperature Measurements Using Isolated Amplifiers (Rev. A)PDF, 145 Kb, Revision: A, Datei veröffentlicht: Aug 11, 2017
The most common thermocouple in use today is the Type K. A Type-K thermocouple is inexpensive accurate and works reliably in harsh environments. Type-K thermocouples can measure temperatures ranging from –200°C to +1250°C and have a Seebeck coefficient of S = 41 μV/K at room temperature. - Interfacing a Differential-Output (Isolated) Amp to a Single-Ended Input ADCPDF, 177 Kb, Datei veröffentlicht: Apr 19, 2017
 
Modellreihe
Serie: AMC1301 (2)
- AMC1301DWV AMC1301DWVR
 
Herstellerklassifikation
- Semiconductors > Amplifiers > Special Function Amplifiers > Isolated Amplifiers