Datasheet Texas Instruments OPA512SM — Datenblatt

HerstellerTexas Instruments
SerieOPA512
ArtikelnummerOPA512SM
Datasheet Texas Instruments OPA512SM

Operationsverstärker mit sehr hohem Strom und hoher Leistung 8-TO-3

Datenblätter

Datasheet
TSP

Preise

Status

Lifecycle StatusNRND (Not recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin8
Package TypeLMF
Industry STD TermTO-CAN
JEDEC CodeO-MBCY-W
Width (mm)25.4
Length (mm)38.86
Thickness (mm)7.11
Pitch (mm)6.35
Max Height (mm)7.62
Mechanical DataHerunterladen

Öko-Plan

RoHSNot Compliant
Pb FreeNo

Anwendungshinweise

  • Heat Sinking- TO-3 Thermal Model
    PDF, 23 Kb, Datei veröffentlicht: Sep 27, 2000
    A critical issue with all semiconductor devices is junction temperature (TJ). TJ must be kept below its maximum rated value, typically 150В°C. The lower the junction temperature the better. The thermal circuit shown allows temperature to be estimated with simple calculations. The temperature rise across each interface is equal to the total power dissipated in the device ti
  • Mounting Considerations for TO-3 Packages
    PDF, 73 Kb, Datei veröffentlicht: Sep 27, 2000
    Proper mounting of TO-3 packages is required to assure rated performance and reliability. Although the procedures are simple, ignoring them can result in poor performance and catastrophic failure of the device.
  • MTTF, Failrate, Reliability, and Life Testing
    PDF, 51 Kb, Datei veröffentlicht: Oct 4, 2000
    At Burr-Brown, we characterize and qualify the reliability of our devices through high temperature life testing. The results of this testing are quantified with such values as MTTF and failure rate. This information can be very valuable when used for comparative purposes or applied to reliablility calculations. However, this information loses its worth if it is not precisely understood and appropr
  • Power Amplifier Stress and Power Handling Limitations
    PDF, 55 Kb, Datei veröffentlicht: Sep 27, 2000
    To achieve reliable power amplifier designs you must consider the stress on the amplifier compared to its power handling limitations. Power handling limits are specified by the Safe Operating Area (SOA) curves of the power amp. Stress on the amplifier depends on amplifier load and signal conditions which can be evaluated with straightforward techniques.

Modellreihe

Serie: OPA512 (2)

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps